Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 88
Filter
1.
Journal of Geriatric Cardiology ; (12): 399-430, 2023.
Article in English | WPRIM | ID: wpr-982208

ABSTRACT

In 2019, cardiovascular disease (CVD) accounted for 46.74% and 44.26% of all deaths in rural and urban areas, respectively. Two out of every five deaths were attributed to CVD. It is estimated that approximately 330 million individuals in China are affected by CVD. Among them, there are 13 million cases of stroke, 11.4 million cases of coronary heart disease, 5 million cases of pulmonary heart disease, 8.9 million cases of heart failure, 4.9 million cases of atrial fibrillation, 2.5 million cases of rheumatic heart disease, 2 million cases of congenital heart disease, 45.3 million cases of lower extremity artery disease, and 245 million cases of hypertension. With the dual challenges of population aging and a steady increase in the prevalence of metabolic risk factors, the burden of CVD in China is expected to continue rising. Consequently, new demands arise for CVD prevention, treatment, and the allocation of medical resources. Emphasizing primary prevention to reduce disease prevalence, increasing the allocation of medical resources for CVD emergency and critical care, and providing rehabilitation services and secondary prevention to reduce the risk of recurrence, rehospitalization, and disability among CVD survivors are of paramount importance. Hypertension, dyslipidemia, and diabetes affect millions of individuals in China. Since blood pressure, blood lipids, and blood sugar levels often rise insidiously, vascular disease and serious events such as myocardial infarction and stroke occur by the time they are detected in this population. Therefore, it is crucial to implement strategies and measures to prevent risk factors such as hypertension, dyslipidemia, diabetes, obesity, and smoking. Furthermore, greater efforts should be directed towards assessing cardiovascular health status and conducting research on early pathological changes to enhance prevention, treatment, and understanding of CVD.

2.
Chinese Journal of Surgery ; (12): 177-180, 2023.
Article in Chinese | WPRIM | ID: wpr-970177

ABSTRACT

The number of patients with heart failure in China is large, and the proportion of patients with end-stage heart failure continues to increase. The clinical effect of guideline-directed medications therapy for end-stage heart failure is poor. Heart transplantation is the most effective treatment for end-stage heart failure. But it is faced with many limitations such as the shortage of donors. In recent years, the research and development of artificial heart in China has made great progress. Three devices have been approved by the National Medical Products Administration for marketing, and another one is undergoing pre-marketing clinical trial. Since 2017, more than 200 cases of ventricular assist device implantation have been carried out in more than 34 hospitals in China. Among them, 70 patients in Fuwai Hospital, Chinese Academy of Medical Sciences had a 2-year survival rate of 90%. The first patient has survived more than 5 years with the device. More efforts should be put into the training of standardized technical team and quality control. Further research should be carried out in the aspects of pulsatile blood flow pump, fully implanted cable-free device, and improved biomaterial with better blood compatibility.


Subject(s)
Humans , Heart-Assist Devices , Heart Failure/surgery , Heart, Artificial , Heart Transplantation , Pulsatile Flow
3.
Chinese Journal of Cardiology ; (12): 393-399, 2023.
Article in Chinese | WPRIM | ID: wpr-984665

ABSTRACT

Objective: To evaluate the long-term efficacy and safety of the implantable ventricular assist system EVAHEART I in clinical use. Methods: Fifteen consecutive patients with end-stage heart failure who received left ventricular assist device therapy in Fuwai Hospital from January 2018 to December 2021 were enrolled in this study, their clinical data were retrospectively analyzed. Cardiac function, liver and kidney function, New York Heart Association (NYHA) classification, 6-minute walk distance and quality of life were evaluated before implantation and at 1, 6, 12, 24 and 36 months after device implantation. Drive cable infection, hemolysis, cerebrovascular events, mechanical failure, abnormally high-power consumption and abnormal pump flow were recorded during follow up. Results: All 15 patients were male, mean average age was (43.0±7.5) years, including 11 cases of dilated cardiomyopathy, 2 cases of ischemic cardiomyopathy, and 2 cases of valvular heart disease. All patients were hemodynamically stable on more than one intravenous vasoactive drugs, and 3 patients were supported by preoperative intra aortic balloon pump (IABP). Compared with before device implantation, left ventricular end-diastolic dimension (LVEDD) was significantly decreased ((80.93±6.69) mm vs. (63.73±6.31) mm, P<0.05), brain natriuretic peptide (BNP), total bilirubin and creatinine were also significantly decreased ((3 544.85±1 723.77) ng/L vs. (770.80±406.39) ng/L; (21.28±10.51) μmol/L vs. (17.39±7.68) μmol/L; (95.82±34.88) μmol/L vs. (77.32±43.81) μmol/L; P<0.05) at 1 week after device implantation. All patients in this group were in NYHA class Ⅳ before implantation, and 9 patients could recover to NYHA class Ⅲ, 3 to class Ⅱ, and 3 to class Ⅰ at 1 month after operation. All patients recovered to class Ⅰ-Ⅱ at 6 months after operation. The 6-minute walk distance, total quality of life and visual analogue scale were significantly increased and improved at 1 month after implantation compared with those before operation (P<0.05). All patients were implanted with EVAHEART I at speeds between 1 700-1 950 rpm, flow rates between 3.2-4.5 L/min, power consumption of 3-9 W. The 1-year, 2-year, and 3-year survival rates were 100%, 87%, and 80%, respectively. Three patients died of multiple organ failure at 412, 610, and 872 d after surgery, respectively. During long-term device carrying, 3 patients developed drive cable infection on 170, 220, and 475 d after surgery, respectively, and were cured by dressing change. One patient underwent heart transplantation at 155 d after surgery due to bacteremia. Three patients developed transient ischemic attack and 1 patient developed hemorrhagic stroke events, all cured without sequelae. Conclusion: EVAHEART I implantable left heart assist system can effectively treat critically ill patients with end-stage heart failure, can be carried for long-term life and significantly improve the survival rate, with clear clinical efficacy.


Subject(s)
Humans , Male , Adult , Middle Aged , Female , Heart Failure/complications , Follow-Up Studies , Retrospective Studies , Heart-Assist Devices , Quality of Life
4.
Chinese Medical Journal ; (24): 1414-1419, 2019.
Article in English | WPRIM | ID: wpr-799956

ABSTRACT

Background@#Perioperative and median-term follow-up outcomes have not been compared among procedures using radiofrequency ablation devices for permanent atrial fibrillation with concomitant rheumatic valve disease. We compared the sinus rhythm restoration efficacy of "non-irrigation" ablation forceps and an "irrigation" ablation device in patients with rheumatic valve disease undergoing a modified Cox maze radiofrequency ablation procedure due to permanent atrial fibrillation.@*Methods@#Data of 278 patients with rheumatic valve disease from the Cardiac Surgery Department of Sichuan Provincial People’s Hospital who underwent the modified Cox maze radiofrequency ablation procedure between May 2013 and May 2017 were reviewed. The procedure was performed using "non-irrigation" ablation forceps (AtriCure, group A) in 149 patients and an "irrigation" ablation device (Medtronic, group M) in 129 patients. Data were collected prospectively, and follow-up was documented and compared between the groups.@*Results@#The radiofrequency procedure duration was 28.9 ± 3.8 min in group A and 29.5 ± 2.8 min in group M (t = 1.623, P = 0.106). The predicted radiofrequency time to the left atrium diameter was (Ya = 0.4964 X + 0.3762, R2 = 0.74) in group A and (Ym = 0.4331 X + 4.3563, R2 = 0.8435) in group M. The sinus rhythm (SR) conversion rate without use of anti-arrhythmic drugs was similarly good in groups A and M, with 75.2%, 72.5%, and 70.5% vs. 73.6%, 71.3%, and 69.8% at discharge, 6 and 12 months, respectively (F = 0.084, F = 0.046, F = 0.046, P > 0.05, respectively).@*Conclusion@#Two types of radiofrequency ablation devices characteristic of "non-irrigation" and "irrigation" bipolar ablation forceps were similarly efficient at SR restoration.

5.
Chinese Medical Journal ; (24): 1414-1419, 2019.
Article in English | WPRIM | ID: wpr-771217

ABSTRACT

BACKGROUND@#Perioperative and median-term follow-up outcomes have not been compared among procedures using radiofrequency ablation devices for permanent atrial fibrillation with concomitant rheumatic valve disease. We compared the sinus rhythm restoration efficacy of "non-irrigation" ablation forceps and an "irrigation" ablation device in patients with rheumatic valve disease undergoing a modified Cox maze radiofrequency ablation procedure due to permanent atrial fibrillation.@*METHODS@#Data of 278 patients with rheumatic valve disease from the Cardiac Surgery Department of Sichuan Provincial People's Hospital who underwent the modified Cox maze radiofrequency ablation procedure between May 2013 and May 2017 were reviewed. The procedure was performed using "non-irrigation" ablation forceps (AtriCure, group A) in 149 patients and an "irrigation" ablation device (Medtronic, group M) in 129 patients. Data were collected prospectively, and follow-up was documented and compared between the groups.@*RESULTS@#The radiofrequency procedure duration was 28.9 ± 3.8 min in group A and 29.5 ± 2.8 min in group M (t = 1.623, P = 0.106). The predicted radiofrequency time to the left atrium diameter was (Ya = 0.4964 X + 0.3762, R = 0.74) in group A and (Ym = 0.4331 X + 4.3563, R = 0.8435) in group M. The sinus rhythm (SR) conversion rate without use of anti-arrhythmic drugs was similarly good in groups A and M, with 75.2%, 72.5%, and 70.5% vs. 73.6%, 71.3%, and 69.8% at discharge, 6 and 12 months, respectively (F = 0.084, F = 0.046, F = 0.046, P > 0.05, respectively).@*CONCLUSION@#Two types of radiofrequency ablation devices characteristic of "non-irrigation" and "irrigation" bipolar ablation forceps were similarly efficient at SR restoration.


Subject(s)
Adult , Female , Humans , Male , Middle Aged , Atrial Fibrillation , Therapeutics , Catheter Ablation , Methods , Cohort Studies , Heart Valve Diseases , Therapeutics , Radiofrequency Ablation , Methods , Retrospective Studies , Rheumatic Heart Disease , Therapeutics , Tricuspid Valve Insufficiency , Therapeutics
6.
Chinese Circulation Journal ; (12): 1098-1101, 2018.
Article in Chinese | WPRIM | ID: wpr-703933

ABSTRACT

Objectives: To compare the short-term and mid-term outcomes of elderly patients (>60 years old) with valvular heart disease (VHD) underwent bioprosthetic or mechanical valve replacement. Methods: Between January 2007 and December 2010, 559 elderly patients underwent valve replacement in Fuwai Hospital, clinical data of these patients were analyzed retrospectively (319 cases with bioprostheses vs 240 cases with mechanical prostheses). After matching, data from 192 cases in each group were compared. Results: The mortality within 30 postoperative days were similar (2.1% in both groups). All-cause death during follow up was also similar between the two groups (13.6% vs 13.7%, P=0.98). There was no statistically significant difference on the hospital readmission rate between the two groups (25.5% vs 35.9%, P=0.17). No significant difference was found on thromboembolic and hemorrhagic events free survival between the two groups (144 cases vs 138 cases, P=0.78). Conclusions: Short-term and mid-term survival and readmission rate are similar for the elderly VHD patients receiving bioprosthetic or mechanical valve replacement.

7.
Chinese Circulation Journal ; (12): 419-423, 2018.
Article in Chinese | WPRIM | ID: wpr-703873

ABSTRACT

Objectives: The purpose of this study was to compare the 30-day clinical outcome after simultaneous hybrid coronary revascularization (HCR) with off-pump coronary artery bypass grafting (OPCABG) in patients with multivessel coronary artery disease and evaluate the safety and efficiency of simultaneous hybrid coronary revascularization strategy. Methods: Simultaneous HCR was performed in 533 patients with multivessel coronary artery disease at Fuwai hospital from January 2009 to January 2017. These patients were 1:1 matched with patients underwent OPCABG using propensity score matching method. The primary endpoint was major adverse cardiac or cerebrovascular events (MACCE) over the 30-day follow-up post-surgery, and the second endpoints were in-hospital outcomes, including chest tube drainage, transfusion rate, mechanical ventilation time and length of stay in intensive care unit. Results: Chest tube drainage post-surgery (ml)(714 [523, 971] vs 965 [716, 1 220], P<0.001),Blood transfusion rate (19.7% vs 34.0%, P=0.024), mechanical ventilation time (hours) (12.6[9.3, 15.7] vs 16.0 [12.8, 18.7], P<0.001), and stay in intensive care unit (hours) (21.7[19.8, 42.4] vs 41.6[23.6, 70.0], P<0.001) were all significantly reduced in the simultaneous HCR group than in OPCABG group. Mortality, myocardial infarction, stroke, repeat revascularization rate and accumulated MACCE rate during the 30-day follow-up were similar between HCR group and OPCABG group .Conclusions: For selected patients with multivessel coronary artery disease, simultaneous HCR provided a safe and effective alternative revascularization strategy. Simultaneous HCR is associated with less blood loss, faster recovery, and fewer perioperative complications and achieved similar and favorable early outcomes as compared with OPCABG strategy.

8.
Chinese Circulation Journal ; (12): 79-82, 2018.
Article in Chinese | WPRIM | ID: wpr-703820

ABSTRACT

Objective: To investigate the safety and efficacy of pulmonary vein deployment technique for percutaneous closure of atrial septal defects (ASD) solely under echocardiography guidance. Methods: A total of 38 ASD patients received pulmonary vein deployment in our hospital from 2012-10 to 2016-09 since the conventional method could not deliver the occluder to correct place. The patients were with the mean age at (16.0±15.6) years, body weight at (37.2±22.9) kg and ASD diameter at (17.1±4.2) mm. Operative effect was assessed by echocardiography. Follow-up study was conducted at 1, 3, 6, 12 months post-operation and at each year thereafter. Results: 37 patients were successfully finished pulmonary vein deployment for percutaneous closure of ASD solely under echocardiography guidance. One patient was successfully treated by a controlled steerable sheath. The mean operative time was (25.2±5.1) min and mean diameter of ASD occluder was (22.9±5.6) mm. 2 patients had trivial residual shunt at the early post-operative stage. No peripheral vascular injury, pulmonary vein and cardiac perforation occurred. All 38 patients were recovered and discharged. The average in-hospital time was (2.9±0.7) days. The patients were followed-up for (23.9±15.4) months, without complications of residual shunt, pericardial effusion, aortic regurgitation and pulmonary vein stenosis. Conclusion: Pulmonary vein deployment technique for percutaneous closure of ASD solely under echocardiography guidance was safe and effective; it can avoid radiation damage and provided a simple and practical method for ASD patients who failed to conventional method under echocardiography guidance.

9.
Chinese Circulation Journal ; (12): 24-29, 2018.
Article in Chinese | WPRIM | ID: wpr-703809

ABSTRACT

Objective: To compare the middle and long term clinical outcomes of one-stop hybrid coronary revascularization, coronary artery bypass grafting (CABG) and percutaneous coronary intervention (PCI) in treating the patients with multivessel coronary artery disease; to explore the optimal indication of one-stop hybrid technology. Methods: Our research included in 3 groups: Hybrid group, n=141 patients received one-stop hybrid coronary revascularization in our hospital from 2006-06 to 2010-16. Meanwhile, 5797 patients received CABG and 4254 received PCI, the major pre-operative risk factors were studied by Logistic regression analysis to calculate propensity score, adjacent matching was used to respectively select 141 subjects from CABG and PCI patients to make 1:1 match with Hybrid group as CABG group and PCI group. EuroSCORE and SYNTAX score were used to make risk stratification in all 3 groups. By EuroSCORE system: low risk ≤ 2, medium risk (3-5) and high risk ≥ 6; by SYNTAX score system: low risk ≤ 24, medium risk (25-29) and high risk ≥ 30. The incidence of major adverse cardiac/cerebral vascular events (MACCE) was compared among 3 groups at different risk stratifications. Results: The mean follow-up time was 4.5 years up to 2015-01. The overall incidence of MACCE was lower in Hybrid group (9.9%) than PCI group (27.7%), P<0.001; while it was similar between Hybrid group and CABG group (19.1%), P=0.150. By EuroSCORE stratification, the incidence of MACCE in low risk and medium risk patients were similar among 3 groups; while in high risk patients, the incidence was lower in Hybrid group than both CABG group (P=0.017) and PCI group (P<0.001). By SYNTAX score stratification, the incidence of MACCE in low risk and medium risk patients were similar among 3 groups; while in high risk patients, the incidence was lower in Hybrid group than PCI group (P<0.001), it was similar between Hybrid group and CABG group (P=0.355). Conclusion: One-stop hybrid technology had the better middle and long term outcomes for treating multivessel coronary artery disease patients with high risk stratification, which provided an alternative strategy in clinical practice.

10.
Chinese Journal of Applied Physiology ; (6): 316-321, 2015.
Article in Chinese | WPRIM | ID: wpr-255025

ABSTRACT

<p><b>OBJECTIVE</b>Since 2011 EB-APS conference, we hypotheses that phase switching of inspiration-expiration is dominantly initiated by oscillatory information PaO2, PaCO2 and [H+] via fast peripheral chemical receptors. However, the evidence of the waveform of ABG is lack.</p><p><b>METHODS</b>Six surgery patients with normal heart function and negative Allen test, had been placed the arterial catheterization directly connected to 3 x 1 000 mm pre-heparin plastic pipe for continuous collecting arterial blood. We counted the number of heart beat for the blood collecting time, and separated the blood pipe into the heart beat numbers' short pieces using haemostatic forceps, then put pipe into iced water at once fir analyzing PaO2, PaCO2, pH and SaO2 as soon as possible. We selected two breaths cycles of waveform from each patient for data calculations of magnitudes and time interval.</p><p><b>RESULTS</b>The heart beat numbers for filling blood into pipe were 16 ± 2, and all covered more than 2 breathing cycles. Each breathing cycle is cover 5 ± 0.6 heart beat. There were significant changes of PaO2, PaCO2, [H+] a and SaO2 (i.e. the highest high values compare to the next lowest values, P < 0.05). The time interval of changing PaO2, PaCO2, [H+]a and SaO2 magnitudes were 11.28 ± 1.13 mmHg, 1.77 ± 0.89 mmHg, 1.14 ± 0.35 nmol/L and 0.52% ± 0.44% respectively.</p><p><b>CONCLUSION</b>This simple continuous beat-by-beat arterial blood sampling and ABG analyzing method is new and practicable. We obtain a clear evidence of periodic parameters ABG waveform, which following breathing cycle.</p>


Subject(s)
Humans , Arteries , Physiology , Blood Gas Analysis , Heart Rate , Monitoring, Physiologic , Methods , Respiration
11.
Chinese Journal of Applied Physiology ; (6): 322-340, 2015.
Article in Chinese | WPRIM | ID: wpr-255024

ABSTRACT

<p><b>OBJECTIVE</b>We investigate the magnitudes of waveform changes of arterial blood gas (ABG) in patients with heart failure.</p><p><b>METHODS</b>Five patients with heart failure were selected, continuous collecting radial artery blood and measured PaO2, PaCO2, pHa and Sao2. We selected two typical breaths cycles of waveform changes of ABG from each patient for data analysis. Comparison of the adjacent highest and lowest values to verify the presence of a periodic waveform changes of ABG, and in addition, we used t test to analysis the range of waveform changes of ABG in patients with heart failure and patients with normal cardiac function and compared whether the difference between them.</p><p><b>RESULTS</b>The 5 patients (2 surgical and 3 ICU) with heart failure, were 4 male and 1 female, (69 ± 7)year, (169 ± 10) cm, (75 ± 19)kg, LVEF = (38 ± 3)%. The heart beat numbers for full blood into the blood sampling pipe were 17 ± 2, and all covered more than 2 breath cycles. There were significant changes of PaO2, PaCO2, [H+]a and SaO2 (P < 0.05). The magnitudes of changing PaO2, PaCO2, [H+]a and Sao2 were (7.94 ± 2.02)mmHg, (1.18 ± 0.56)mmHg, (0.54 ± 0.17)nmol/L and (0.21 ± 0.07)%, and they were (6.1 ± 1.5)%, (3.2 ± 1.5)%, (1.5 ± 0.5)% and (0.2 ± 0.1)% from their mean respectively. Even these magnitudes fo all ABG parameters were trendily lower than those of patients with normal cardiac function, but only PaO2 and [H+]a were significant (P < 0.05).</p><p><b>CONCLUSION</b>Using this simple continuous beat-by-beat arterial blood sampling method, we obtained a clear evidence of periodic waveform of ABG parameters following by breath cycle in patients with heart failure, but the magnitude trendily be decreased.</p>


Subject(s)
Aged , Female , Humans , Male , Middle Aged , Blood Gas Analysis , Cardiovascular Diseases , Heart Failure , Heart Rate , Monitoring, Physiologic , Methods
12.
Chinese Journal of Applied Physiology ; (6): 332-336, 2015.
Article in Chinese | WPRIM | ID: wpr-255021

ABSTRACT

<p><b>OBJECTIVE</b>For heart functional parameters, we commonly used normal range. The reference values and predict formulas of heart functional parameters and their relationships with individual characteristics are still lack.</p><p><b>METHODS</b>Left ventricular (LV) volumes (end-diastolic volume and end-systolic volume), stroke volume (SV), ejection fraction (EF) and cardiac output (CO) were measured by cardiac CT angiography (CAT) in 1 200 healthy Caucasian volunteers, men 807 and women 393, and age 20-90yr. The results are analyzed by high-accuracy three-dimensional imaging technology, and then measured the dynamic changes of the volumes of each atriam and ventricule during their contractions and relaxations. The gender, age, height and weight were analyzed by multiple linear regression to predict LV functional parameters.</p><p><b>RESULTS</b>Except the LVEF was lower in man than in women (P < 0.001), all other LV functional parameters of EDV, ESV, SV, FE and CO were higher in man (P < 0.001). Multiple linear regression indicated that age, gender, height and weight are all independent factors of EDV, ESV and SV (P < 0.001). CO could be significantly predicted by age, gender and weight (P < 0.001), but not height (P > 0.05). The predict equation for CO (L x min(-1)) = 6.963+0.446 (Male) -0.037 x age (yr) +0.013 x weight (kg).</p><p><b>CONCLUSION</b>Age, gender, height and weight are predictors of heart functions. The reference values and predict equations are important for noninvasive and accurate evaluation of cardiovascular disease and individualized treatment.</p>


Subject(s)
Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Young Adult , Age Factors , Body Height , Body Weight , Cardiac Output , Heart , Physiology , Reference Values , Sex Factors , Stroke Volume , Ventricular Function, Left
13.
Chinese Journal of Applied Physiology ; (6): 357-360, 2015.
Article in Chinese | WPRIM | ID: wpr-255015

ABSTRACT

<p><b>OBJECTIVE</b>This study aimed to investigate the feature of D(L)CO (Diffusion Lung Capacity for Carbon Monoxide) in CHF (left ventricular heart failure) patients, underlying pathophysiological mechanism and clinical significance.</p><p><b>METHODS</b>We retrospectively studied the D(L)CO, pulmonary ventilation function, cardiopulmonary exercise testing and related clinical information in severer HF patients.</p><p><b>RESULTS</b>Peak VO2 severely decreased to 34 ± 7 percentage of predicted(%pred) and anaerobic threshold to 48 ± 11%pred in all patients. D(L)CO moderately decreased to 63 ± 12%pred and there were 25 patients lower than 80%pred. FVC, FEV1, FEV1/FVC and TLC were 75 ± 14%pred, 71 ± 17%pred, 97 ± 11%pred, and 79 ± 13%pred, which indicated borderline or mild restrictive ventilatory dysfunction. The decrease of D(L)CO was more severe than those of TLC, FEV1 and FVC.</p><p><b>CONCLUSION</b>For patients with severe CHF, cardiopulmonary exercise function is extremely limited, D(L)CO generally moderately declines and ventilation function is merely mildly limited. D(L)CO is the parameter for cardiopulmonary coupling, reflecting limitation of the cardiovascular dysfunction while without ventilatory limit.</p>


Subject(s)
Humans , Blood Gas Analysis , Heart Failure , Respiratory Function Tests , Retrospective Studies , Ventricular Dysfunction, Left
14.
Chinese Journal of Applied Physiology ; (6): 508-516, 2015.
Article in English | WPRIM | ID: wpr-254980

ABSTRACT

<p><b>OBJECTIVE</b>Measures of ventilation-CO₂output relationship have been shown to be more prognostic than peak O₂uptake in assessing life expectancy in patients with chronic heart failure (CHF). Because both the ratios (VE/Vco₂) and slopes (VE-vs-Vco₂) of ventilation-co₂ output of differing durations can be used, we aim to ascertain which measurements best predicted CHF life expectancy.</p><p><b>METHODS</b>Two hundred and seventy-one CHF patients with NYHA class II-IV underwent incremental cardiopulmonary exercise testing (CPET) and were followed-up for a median duration of 479 days. Four different linear regression VE-vs- Vco₂ slopes were calculated from warm-up exercise onset to: 180 s, anaerobic threshold (AT), ventilatory compensation point (VCP); and peak exercise. Five VE/Vco₂ ratios were calculated for the following durations: rest (120 s), warm-up (30 s), AT (60 s), lowest value (90 s), and peak exercise (30 s). Death or heart transplant were considered end-points. Multiple statistical analyses were performed.</p><p><b>RESULTS</b>CHF patients had high lowest VE/Vco₂ (41.0 ± 9.2, 141 ± 30%pred), high VE/Vco₂ at AT (42.5 ± 10.4, 145 ± 35%pred), and high VE-vs-Vco₂ slope to VCP (37.6 ± 12.1, 126 ± 41%pred). The best predictor of death was a higher lowest VE/Vco₂ (≥ 42, ≥ 141%pred), whereas the VE-vs-Vco₂slope to VCP was less variable than other slopes. For death prognosis in 6 months, %pred values were superior: for longer times, absolute values were superior.</p><p><b>CONCLUSION</b>The increased lowest VE/Vco₂ ratio easily identifiable and simply measured during exercise, is the best measurement to assess the ventilation-co₂output relationship in prognosticating death in CHF patients.</p>


Subject(s)
Humans , Carbon Dioxide , Metabolism , Chronic Disease , Disease Progression , Exercise Test , Heart Failure , Diagnosis , Mortality , Life Expectancy , Respiratory Function Tests
15.
Chinese Journal of Applied Clinical Pediatrics ; (24): 1787-1792, 2013.
Article in Chinese | WPRIM | ID: wpr-733222

ABSTRACT

Objective To retrospectively study 50 children with anomalous origin of the left coronary artery from the pulmonary artery(ALCAPA) and find the simple and practical indexes that may predict myocardial viability and the possible risk factors that may affect the choice of operation and the recovery after surgery.Methods A retrospective study was performed in 50 children with ALCAPA [29 male,21 female,aged from 4 months to 18 years,average (4.49 ±4.30) years] between Apr.1999 and Mar.2013.The preoperative examination included electrocardiogram (ECG),echocardiography,chest X-ray,mutislice spiral computerized tomography (MSCT),angiocardiography et al.Follow-up data were obtained by reviewing the records made in out-patient and recent telephone call.According to myocardial 18F-FDG imaging,the extent of myocardial viability of 15 patients with ALCAPA was classified into 4 grades.0 normal myocardial; 1 viable myocardial ;2 partial viable myocardial;3 myocardial infarction.Meanwhile,the global clinical scores were calculated and divided into 10 levels according to the deviations of clinical manifestations which included abnormal Q waves,left ventricular ejection fraction (LVEF),left ventricular end-diastolic dimension (LVED),cardiothoracic ratio(CTR),intercoronary collaterals(ICC),mitral regurgitation(MR) and aneurysm.The relationship of the extent of myocardial viability and clinical features were studied.All patients with ALCAPA were classified into groups by the global clinical scores and the preoperative,perioperative and post operative clinical manifestations were compared among groups.Results The extent of myocardial viability was related well to the global clinical scores (r =0.936,P <0.001),LVEF(r =0.783,P < 0.001),CTR (r =0.770,P < 0.002),abnormal Q waves (r =0.667,P < 0.01) and LVED (r =0.637,P < 0.02),but was not related to age,MR and ICC (r =-0.206,-0.268,-0.342,all P > 0.05).The results showed that grade 0-1 equaled scores 0-3,grade 2 equaled scores 3-5,grade 3 equaled scores > 5.Chil-dren with less viable myocardium had more severe clinical symptoms.Among abnormal Q waves,LVEF < 50%,CTR >0.65,ICC dysplasia,median to severe MR and the global clinical scores > 3,the global clinical scores > 3 and LVEF <50% showed a good predict of myocardial infarction.The preoperative,perioperative and post operative clinical manifestations were compared between 2 groups divided by the global clinical scores (group A,scores ≤ 3 and group B,scores >3) in all patients.More infants and toddlers,abnormal Q waves,ICC dysplasia,RCA/AO <0.2,larger CTR and lower LVEF were found in group B than those in group A.The time of cross-clamp and CPB was not different between the 2 groups,but the postoperative ventilation time and postoperative ICU stay were longer in group B than in group A.Fortyseven patients underwent operation and there were no operative deaths.One infant with scores 9 died while waiting heart transplantation.Follow-ups from 1 to 168 months were conducted in 38 patients(80.9%,38/47 cases) and 1 patient with ligation of the left coronary artery (LCA) had a sudden death after 8 months of surgery.All patients had gotten smaller LVED after surgery.Nineteen patients had mild MR and 3 patients had mild supravalvular pulmonary stenosis in following-up.Of the 16 patients with LVEF < 50%,14 had a recovery of LVEF,2 patients still had LVEF < 50%.Conclusions In children with ALCAPA,the extent of myocardial viability evaluated by myocardial 18 F-FDG imaging is related closely to the preoperative clinical manifestations.The global clinical scores > 3 and LVEF < 50% have a good predict of myocardial infarction.Even in young children with severely depressed left ventricular function,higher global clinical scores and more myocardial infarction,median and long-term follow-ups showed satisfactory recovery of cardiac function after successful restoration of a dual coronary arterial system.

16.
Chinese Medical Journal ; (24): 450-456, 2013.
Article in English | WPRIM | ID: wpr-342563

ABSTRACT

<p><b>BACKGROUND</b>The hybrid procedure for coronary heart disease combines minimally invasive coronary artery bypass grafting (CABG) and percutaneous coronary intervention (PCI) and is an alternative to revascularization treatment. We sought to assess the predictive value of four risk-stratification models for risk assessment of major adverse cardiac and cerebrovascular events (MACCE) in patients with multivessel disease undergoing hybrid coronary revascularization.</p><p><b>METHODS</b>The data of 120 patients were retrospectively collected and the SYNTAX score, EuroSCORE, SinoSCORE and the Global Risk Classification (GRC) calculated for each patient. The outcomes of interest were 2.7-year incidences of MACCE, including death, myocardial infarction, stroke, and any-vessel revascularization.</p><p><b>RESULTS</b>During a mean of 2.7-year follow-up, actuarial survival was 99.17%, and no myocardial infarctions occurred. The discriminatory power (area under curve (AUC)) of the SYNTAX score, EuroSCORE, SinoSCORE and GRC for 2.7-year MACCE was 0.60 (95% confidence interval 0.42 - 0.77), 0.65 (0.47 - 0.82), 0.57 (0.39 - 0.75) and 0.65 (0.46 - 0.83), respectively. The calibration characteristics of the SYNTAX score, EuroSCORE, SinoSCORE and GRC were 3.92 (P = 0.86), 5.39 (P = 0.37), 13.81 (P = 0.32) and 0.02 (P = 0.89), respectively.</p><p><b>CONCLUSIONS</b>In patients with multivessel disease undergoing a hybrid procedure, the SYNTAX score, EuroSCORE, SinoSCORE and GRC were inaccurate in predicting MACCE. Modifying risk-stratification models to improve the predictive value for a hybrid procedure is needed.</p>


Subject(s)
Aged , Female , Humans , Male , Middle Aged , Angioplasty, Balloon, Coronary , Methods , Coronary Artery Bypass , Methods , Coronary Artery Disease , Mortality , General Surgery , Therapeutics
17.
Chinese Journal of Cardiology ; (12): 215-218, 2013.
Article in Chinese | WPRIM | ID: wpr-291998

ABSTRACT

<p><b>OBJECTIVE</b>To access the prevalence and risk factors for hypertension after heart transplantation (HT), and the impact of post-transplant hypertension on medium-term survival among HT patients.</p><p><b>METHODS</b>Data from 265 consecutive patients underwent HT between June 2004 and May 2012 in Fuwai hospital and survived for at least 6 months were retrospectively analyzed. Hypertension was defined as systolic pressure ≥ 140 mm Hg (1 mm Hg = 0.133 kPa) and/or diastolic pressure ≥ 90 mm Hg or current treatment with antihypertensive drugs. Patients were divided into post-HT hypertension group and non-hypertension group. Logistic regression analysis was used to determine preoperative and postoperative risk factors for hypertension after HT. Kaplan-Meier method and log rank test were used for survival analysis.</p><p><b>RESULTS</b>Hypertension was present in 17.4% (46/265) patients before HT and in 57.4% (152/265) patients post HT. The median follow-up time was 37 months (20 - 57 months). Logistic regression analysis showed that male gender (OR: 2.27, 95%CI: 1.16 - 4.42, P < 0.05), history of pre-HT hypertension (OR: 2.22, 95%CI: 1.05 - 4.71, P < 0.05), and cyclosporine A based immunosuppressive therapy (OR: 2.54, 95%CI: 1.51 - 4.29, P < 0.01) were independent risk factors for the development of post-HT hypertension. At the end of 1, 3, 5 years, the survival rate of heart transplant patients by Kaplan-Meier method estimation were 100%, 97.2%, 86.7% in post-HT hypertension group; 98.1%, 93.8%, 93.8% in non-hypertension group. Log rank test displayed that there was no significant difference between the two survival curves (P > 0.05).</p><p><b>CONCLUSIONS</b>Hypertension is a frequent comorbidity after HT. Male gender, pre-HT hypertension together with cyclosporine A based immunosuppressive therapy are independent predictors for the development of post-HT hypertension. By adjusting the controllable risk factors and active control of blood pressure, the medium-term survival is similar between patients with or without postoperative hypertension in this cohort.</p>


Subject(s)
Adult , Female , Humans , Male , Middle Aged , Heart Transplantation , Hypertension , Logistic Models , Postoperative Complications , Prognosis , Retrospective Studies , Risk Factors
18.
Chinese Journal of Cardiology ; (12): 598-601, 2013.
Article in Chinese | WPRIM | ID: wpr-261488

ABSTRACT

<p><b>OBJECTIVE</b>To analyze the clinical features, precaution and management of complete heart block (CHB) after transaortic extended septal myectomy operation (extended Morrow procedure) in patients with hypertrophic obstructive cardiomyopathy (HOCM).</p><p><b>METHODS</b>From October 1996 to December 2011, 10[6 men; mean age (45.4 ± 15.8) years, range 13-60 years] out of 160 consecutive HOCM patients underwent extended Morrow procedure developed CHB postoperatively. Their clinical data were retrospectively analyzed. Baseline transthoracic echocardiography showed that the left ventricular outflow tract (LVOT) gradients was from 68 to 149 (105.1 ± 25.9) mm Hg (1 mm Hg = 0.133 kPa), ECG showed right bundle branch block in 5 patients and atrial fibrillation, atrial premature beats or ST-T segment changes in other 5 patients. Besides extended Morrow procedure, concomitant surgical procedures included mitral valve replacement (MVR) in 2 (2/10) and MVR plus coronary artery bypass grafting in another 2 (2/10) patients. Follow-up data were obtained by subsequent clinic visits in outpatient department and telephone interviews.</p><p><b>RESULTS</b>The in-hospital mortality was 20% (these two patients died of low cardiac output syndrome and multiple organs failure). Four patients underwent MVR simultaneously survived the operation. Postoperative echocardiography demonstrated a reduced LVOT gradient[(13.6 ± 9.7) mm Hg, P < 0.001]. Permanent pacemakers were implanted in all 8 survived patients at 6 days to 7 months after operation. No other severe complications were observed. During follow-up [from 4 to 72 (19.4 ± 22.1) months], there was no death, 1 patient readmitted to our center at 71 months post operation to change the pacemaker because of low voltage of previously implanted pacemaker. Physical capacity and quality of life improved significantly post operation in these 8 patients. The NYHA functional class remained at I-II post operation and during follow up.</p><p><b>CONCLUSIONS</b>CHB is a severe complication after extended Morrow procedure for patients with HOCM and timely permanent pacemaker implantation is mandatory for patients with post procedure CHB.</p>


Subject(s)
Adolescent , Adult , Female , Humans , Male , Middle Aged , Young Adult , Atrioventricular Block , Cardiomyopathy, Hypertrophic , General Surgery , Postoperative Complications , Retrospective Studies , Treatment Outcome
19.
Chinese Journal of Cardiology ; (12): 744-746, 2013.
Article in Chinese | WPRIM | ID: wpr-261476

ABSTRACT

<p><b>OBJECTIVE</b>To assess the safety and effectiveness of percutaneous transcatheter closure of atrial septal defect (ASD) under transesophageal echocardiography (TEE) guidance in children.</p><p><b>METHODS</b>The study included 20 cases of patients with ASD. The patients were (4.2 ± 1.2) years old and the mean body weights were (18.2 ± 4.2) kg. The diameter of ASD before closure was (13.4 ± 3.3) mm . All procedures were guided under TEE. Procedure success was evaluated by TEE immediately after procedure.</p><p><b>RESULTS</b>Closure devices were successfully implanted in all 20 patients under TEE guidance. The diameter of closure devices was 14-26 mm. There were no procedure related complications. The ventilation time was (2.9 ± 0.8)h and the hospitalization time was (3.2 ± 0.7) days.</p><p><b>CONCLUSION</b>TEE guided percutaneous transcatheter closure is safe and effective for patients with ASD and avoids the radiation damages.</p>


Subject(s)
Child , Child, Preschool , Female , Humans , Male , Catheterization , Methods , Echocardiography, Transesophageal , Methods , Heart Septal Defects, Atrial , Therapeutics
20.
Chinese Journal of Cardiology ; (12): 681-683, 2012.
Article in Chinese | WPRIM | ID: wpr-326443

ABSTRACT

<p><b>OBJECTIVE</b>To observe the efficacy of hybrid balloon valvuloplasty for the treatment of low-body weight infants with severe congenital valvular aortic stenosis (AS).</p><p><b>METHODS</b>Five infants with severe congenital valvular aortic stenosis underwent the hybrid balloon aortic valvuloplasty through median sternotomy in the hybrid operating room. The mean age was (40.2 ± 7.0) days, weight was (4.48 ± 0.75) kg. The patients were followed up by echocardiography for 9 - 13 months post procedure.</p><p><b>RESULTS</b>Operation was successful in all 5 patients and they were discharged from hospital uneventfully. The gradient pressure decreased significantly from (98.8 ± 9.0) mm Hg (1 mm Hg = 0.133 kPa) to (13.8 ± 3.3) mm Hg (P < 0.05) post operation. There was no moderate or severe aortic insufficiency. All patients were alive, the gradient pressures was (18.8 ± 2.5) mm Hg and there was no moderate or severe aortic insufficiency during follow-up [9 - 13 (11.0 ± 1.4) months].</p><p><b>CONCLUSION</b>The hybrid balloon aortic valvuloplasty is an effective option for the low-body weight infants with severe congenital valvular aortic stenosis.</p>


Subject(s)
Female , Humans , Infant , Infant, Newborn , Male , Aortic Valve Stenosis , General Surgery , Balloon Valvuloplasty , Infant, Low Birth Weight
SELECTION OF CITATIONS
SEARCH DETAIL